part nunber gxt-1000mtplusc230 Technology True Online Capacity (VA/W) 1000/900 Input Parameters Frequency Range 40Hz ~ 70 Hz Phase Single phase with ground Power Factor = 0.99 @ 220 to 230 VAC (input voltage)
Voltage Range
Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC ฑ 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) Low Line Comeback 175 VAC ฑ 5 % High Line Transfer 300 VAC ฑ 5 % High Line Comeback 290 VAC ฑ 5 %
Output Parameters
Output Voltage 208/220/230/240VAC AC Voltage Regulation ฑ 3% (Batt. Mode) Frequency Range 47 to 53 Hz or 57 to 63 Hz (Synchronized Range) Frequency Range (Batt. Mode) 50 Hz ฑ 0.25Hz Overload 100% to 110%: audible warning 110% to 130%: UPS shuts down in 30 seconds at battery mode or transfers to bypass mode when the utility is normal. >130%: UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal. Current Crest Ratio 3:1 Harmonic Distortion = 3 % THD (Linear Load) = 6 % THD (Non-linear Load) Waveform (Batt. Mode) Pure Sinewave
Efficiency
AC Mode ~ 85% Battery Mode ~ 83% Transfer Time AC Mode to Batt. Mode Zero Inverter to Bypass 4 ms (Typical) Battery Charger (Standard Model) Battery Type 12 V / 7 AH Numbers 3 Charging Current 4.0 A or 8.0 A(max.) Charging Voltage 41.0 VDC ฑ 1%
Physical Parameters
Dimension, D X W X H 220 x 145 x 397 Net Weight (kgs) 13
Emvironmental Parameters
Operation Humidity 20 to 90 % RH @ 0 to 40ฐC (non-condensing) Noise Level Less than 55dBA @ 1 Meter Management 4.0 A or 8.0 A(max.) Smart RS-232 or USB Supports Windows 98/2000/2003/XP/Vista/2008/ 7, Linux, and MAC
Optional SNMP
Power management from SNMP manager and web browser 3 Yrs OnSite Replacement By Vertiv
Features
Double conversion on-line technology Compact tower design Standard models and long backup models available Extended runtime capabilities by building up additional battery resources Flexible (site specific) battery configuration Standard model comes with internal battery Generator-compatible with wide input frequency range (40 to 70 Hz) 0.8 output power factor Class A electromagnetic interference (EMC) Ultra wide input voltage range High input power factor & low THDi Emergency power off (EPO) Configurable to energy saving mode (ECO) LCD display for operational convenience and status / fault information Multiple AC output interfaces via IEC standard sockets with Programmable output Remote Monitoring is available through USB / RS232, and optional via dry contacts and SNMP GXT-1000MTPLUS230
PRODUCT OVERVIEW
Power Rating 1000VA / 800W Output Voltage 208/220/230/240VAC
GXT-1000MTPLUS230
The Liebert® GXT MT+ features best-in-class power protection for critical applications with the use oftrue on-line double conversion technology. The Liebert® GXT MT+ has a comprehensive specification that provides a higher level of availability to the IT equipment. It satisfies safety criteria and electromagnetic compatibility standards while offering intelligent monitoring and network management functions. This high performance UPS with proven reliability is available in a compact tower design.
Best Suited For:
Banking, Financial and Insurance Broadcast and Entertainment Education Government Healthcare Retail and Wholesale
Benefits
The Liebert GXT-MT Plus is ideally suited for:
Small Size Data Center Telecommunication Equipment VoIP Small Offi ce Network Computer Rooms Process Automation Equipment Network Storage Devices
What's in the box?
UPS Module Battery Connection Cable only with Long Backup models RS 232 Cable / USB Cable UPS Monitoring Software (to be downloaded from internet) User Manual IEC Output cables x 2 CEE7/7 to IEC-C20 and BS1363 to IEC-C20 input power cord (3KVA model