Cleanline model T-3000 ( ตัวเครื่องเป็นแบบตั้งพื้น ระบบออนไลน์ ups)
Power Rating
3kVA/2.7kW ( 3000va2700watts)
Input
ไฟขาเข้า
Vlotage 110-300Vac at 50% load, 160-300Vac at 100% load
Frequency 50 or 60Hz ±10%
Phase Single phase with ground
Power factor >0.99 @ nominal voltage (100% Load)
Output
ไฟขาออก
Voltage 208/220/230/240Vac
Voltage regulation ±1%
Frequency 50 or 60Hz ±0.1% (Battery mode)
Overload recovery Auto transfer to UPS
UPS Design Technology True on-line double conversion, Full digitized microprocessor controlled
Crest factor 3 : 1
Hamonic distortion ≤2% THD (Linear load), ≤4% THD (Non-Linear load)
Output waveform Pure sinewave
Transfer time 0 ms
Efficiency
ประสิทธิภาพ
AC mode >91%, Battery mode >90%, ECO mode > 97%
Protection and Filtering
Surge protection 220V (IEEEC6100-4-5 level 3)
Overload protection UPS Automatic bypass if overload between 110% to 130% at 30 seconds and more than 130% at 1.5 seconds
Short circuit protection UPS Output cut off immediately or input fuse/circuit breaker protection
Battery
แบตเตอรี่
Type Sealed, Maintenance-free lead acid batteries
Typical recharge time to 90% 4 hrs
Management Self-test
Battery protection Cut off without draining any current when battery is low
Cold start (DC start) yes
Back up time 15-30 minutes (Depending on computer load)
Expansion back up time Depending on customer required
Indicators
ตัวแสดงสถานะ
Status UPS status, Load level, Battery level, Input/output voltage,
Remaining backup time, and Fault conditions
Audible Alarm
เสียงเตือน
Battery mode Sounding every 4 seconds
Low battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
Diminsion 421 x 190 x 318 mm, Weight 27 Kgs
Environmental
Operating Temperature 0-40 °c
Relative humidity 0-95% (Non-Condensing)
Noise level <45dB@1 Meter
Interface
ช่องที่ต่อกับอุปกรณ์ภายนอก
Smart RS232 Software supports windows family, Linux, Sun solarris,
IBM aix, Compaq true64, SGI IRIX, FreeBSD, HP-UX and MAC
USB Windows family and MAC OS
SNMP(option )Power management from SNMP manager and web browser
2 years warranty ( Onsite service )




Cleanline UPS T-1500
Capacity : 1500VA/1350W
True On-line Double Conversion Design
2 years warranty - Onsite service
( bangkok and metropolitan area )
ราคา update บาท (#0.00บาท vat)
Cleanline UPS T-2000
Capacity : 2kVA/1800W
True On-line Double Conversion Design
2 years warranty - Onsite service
( bangkok and metropolitan area )
ราคา update บาท (#0.00บาท vat)
Cleanline UPS T-1000
Capacity : 1kVA/900W
True On-line Double Conversion Design
2 years warranty - Onsite service
( bangkok and metropolitan area )
ราคา update บาท (#0.00บาท vat)
ลูกค้าสามารถติดต่อ เพิ่มเติมได้ที่ 088 758 4005 080 964 2745 096 308 9747 088 758 4003 088 758 4005
ลูกค้าสามารถติดต่อ เพิ่มเติมได้ที่ 088 758 4005 080 964 2745 096 308 9747 088 758 4003 088 758 4005 080 964 2745
Cleanline T-3000 [ tower model ]
ffice hours : 8:30 - 17:30 ( Monday - Friday )
Tel 0 2952 7823
เครื่องสำรองไฟ
cleanline T-3000
เป็นเครื่องสำรองไฟ ที่เหมาะกับ server อุปกรณ์ ทางการแพทย์ และอุปกรณืที่ต้องการไฟเสถียร รุ่นนี้ มาพร้อมกับ กำลังไฟ 3000va 2700watts เป็นระบบ true online มีปลั๊กด้านหลังเครื่องจำนวน 6 ช่อง และมีช่องที่สามารถต่อกับอุปกรณ์ภายนอก เครื่องรุ่นนี้ รับประกัน 2 ปี onsite ถึงที่ สอบถามรายละเอียดเพิ่มเติมได้ที่นี้ เลยค่ะ