Cleanline Model TR-2000
Power Rating
2kVA/1,800W
Input
Vlotage 110-300Vac at 50% load, 160-300Vac at 100% load
Frequency 50 or 60Hz ±10%
Phase Single phase with ground
Power factor >0.99 @ nominal voltage (100% Load)
Output
Voltage 208/220/230/240Vac
Voltage regulation ±1%
Frequency 50 or 60Hz ±0.1% (Battery mode)
Overload recovery Auto transfer to UPS
UPS Design Technology True on-line double conversion, Full digitized microprocessor controlled
Crest factor 3 : 1
Hamonic distortion ≤2% THD (Linear load), ≤4% THD (Non-Linear load)
Output waveform Pure sinewave
Transfer time 0 ms
Efficiency
AC mode >91%, Battery mode >89%, ECO mode > 97%
Protection and Filtering
Surge protection 220V (IEEEC6100-4-5 level 3)
Overload protection UPS Automatic bypass if overload between 110% to 130% at 30 seconds and more than 130% at 1.5 seconds
Short circuit protection UPS Output cut off immediately or input fuse/circuit breaker protection
Battery
Type Sealed, Maintenance-free lead acid batteries
Typical recharge time to 90% 4 hrs
Management Self-test
Battery protection Cut off without draining any current when battery is low
Cold start (DC start) yes
Back up time 15-30 minutes (Depending on computer load)
Expansion back up time Depending on customer required
Indicators
Status UPS status, Load level, Battery level, Input/output voltage, Remaining backup time, and Fault conditions
Audible Alarm
Battery mode Sounding every 4 seconds
Low battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
Diminsion 600 x 438 x 88 (2U) mm, Weight 25.7 Kgs
Environmental
Operating Temperature 0-40 °c
Relative humidity 0-95% (Non-Condensing)
Noise level <45dB@1 Meter
Interface
Smart RS232 Software supports windows family, Linux, Sun solarris,
IBM aix, Compaq true64, SGI IRIX, FreeBSD, HP-UX and MAC
USB Windows family and MAC OS
SNMP(option )Power management from SNMP manager and web browser
2 years warranty ( Onsite service )


Cleanline UPS TR-3000
Capacity : 3kVA/2700W
True On-line Double Conversion Design
19"Rack-mount model
2 years warranty - Onsite service
( bangkok and metropolitan area )
ราคา update บาท (#0.00บาท vat)
Cleanline UPS TR-1000
Capacity : 1kVA/900W
True On-line Double Conversion Design
19"Rack-mount model
2 years warranty - Onsite service
( bangkok and metropolitan area )
ราคา update บาท (#0.00บาท vat)
Cleanline UPS TR-1500
Capacity : 1500VA/1350W
True On-line Double Conversion Design
19"Rack-mount model
2 years warranty - Onsite service
( bangkok and metropolitan area )
ราคา update บาท (#0.00บาท vat)
CLEANLINE TR-2000 True On-line Double Conversion
เครื่องสำรองไฟ Cleanline UPS TR-2000 Rack Mount 2000VA/1800W, True online UPS,
สำรองไฟได้นาน 10-30 นาที ขึ้นอยู่กับอุปกรณ์ต่อพ่วง
ป้องกัน ไฟกระชาก ไฟตก ไฟเกิน และไฟดับ
ติดตั้งฟรี รับประกัน 2 ปี Onsite Service กรุงเทพฯ-ปริมณฑล
ลูกค้าสามารถติดต่อ เพิ่มเติมได้ที่ 088 758 4005 080 964 2745 096 308 9747 088 758 4003 088 758 4005
ลูกค้าสามารถติดต่อ เพิ่มเติมได้ที่ 088 758 4005 080 964 2745 096 308 9747 088 758 4003 088 758 4005 080 964 2745
Cleanline TR-2000 [ rack model ]
ffice hours : 8:30 - 17:30 ( Monday - Friday )
Tel 0 2952 7823
เครื่องสำรองไฟ cleanline TR-2000 เป็นรุ่น rack model กำลังไฟ 2000 va 1800 วัตต์ เครื่องรุ่นนี้ เป็นระบบ true online ups มีการแสดงสถานะผ่านหน้าจอ LCD การรับประกัน 2 ปี เต็ม